Solar Charging & Discharging Controller

C2415 USER MANUAL

    

 

 Thank you for purchasing our solar charging & discharging controller. Please read these instructions before use. 

Our controller named as follow: (Please confirm the item No. before you place orders, so that we can prepare it for you in time.)

C 24 15
 |  |  |  

 |  |  |________15: maximum current (A), 15= 15
 |  |__________ 24: system voltage (V), 24 =24V/12V automatic recognition 
 |_____________ C: solar universal controller

Function

1. It adopts micro-CPU and has the SOC (state of charge) battery system control function.

2. Control the charging and discharging for the battery.

3. When the battery voltage is too low, the controller stops the power supply for load to prevent the battery from over-discharging.

4. The controllers will float-charge the batteries by pulse-width-modulation (PWM) automatically as the batteries approach full charge.

5.  Prevent the battery from reverse charging to solar panels during nights.

6. The controller also has a protection circuit to prevent accidental damage. 

7. IP Grade: IP 22

Connection

As indicated in diagram: 

1. Connect the “+” and “-“poles of the solar panels to the correct terminals on the controller the (the first and second from the left).

2. Connect the”+” and “-“poles of the battery to the correct terminals on the controller (the third and fourth from the left). 

3. Connect “+” and “-“poles of the load to the correct terminals on the controller (the fifth and sixth from the left).

Attention:

A. Don’t use power from the illumination of light for the solar panel. (The power of the light is too low to charge the battery.)

B. Please dont use other DC power source instead of the solar panel, otherwise it will damage the controller.

Notice

Please check the rated voltage of solar panels, battery, and load before connecting. Make sure their rated voltage should be all 12v (or 24v). When you 

install the system, you must firstly connect the controller to the battery, and then connect it to the solar panel or DC load.

1. Pay more attention to “+” and “-“poles of solar panels, battery, controller and loads during the process of connection.

2. The rated current of solar panels and loads must be lower than the controller.

3. Please reference to below technical parameter to choose the right wire size according to the current.

4. Keep the controller away from water and wet, in order to avoid short-circuit.

5. Make sure the connection steady, ensure connect well.

The terminal must be against oxidation and mould, to make sure the connection is in good condition.

Indicator light

Color-changing LED working voltage indicate range (No Load)

Color-changing LED

12V

24V

48V

    Red  LED

10.5V-11V

21V-22V

42-44V

   Orange LED

11V-13.7V

2122V-27.4V

4244V -54.8V

   Green LED

≥13.7V

≥27.4V

≥54.8V

1. The battery is in buck charge stage when the red indicator light (CHARGE) is on. The battery is in float-charge stage when this LED is flickering, and the battery is stopped charging when the LED is off.

2. When the green indicator light ( LIGHT ) is on, it means the load can work; when its off, it means the load can not work.

3. When the power indicator light (BATTERY) is red means the battery is in low voltage, green means the battery is full charged and orange means 

the battery is under normal situation. 

Technical Index:

Model

C2415 6A

C2415 10A

C2415 15A

Rated Voltage

12V/24V   Automatic voltage recognition

Max Load current

6A

10A

15A

Input voltage range

12V20V/24V40V

Max wire Length≤1m

 Charge loop drop

0.25V

Length≤1m

Discharge loop drop

0.05V

Over voltage protection

20V/40V

Full charge cut

13.7V-14.4V/27.4V-28.8V

Low voltage cut

10.5~11V/21V~22V

Temperature compensation

-3mv//cell

No load loss

≤10mA

Max wire area

2.5mm2

Ambient temperature 

-25——55

Trouble Shooting

PhenomenonGreen light goes out, battery power indicator shows red.

ReasonLow voltage of battery

SolutionA. Cut off load, re-connect the load after recharging the battery.

B. There is something trouble with battery, increase solar panel’s power or change battery.

Phenomenon Green Load indicator light and Orange battery indicator are on, the loads stop working

ReasonOverload or Short circuit happens which caused the fuse of the controller cut off

Solution:  Reduce the overload or solute the load circuit of the battery, 10-20 minutes later, the fuse can reconnect automatically.               

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Content:
Verification code: captcha
                        

Products  |  Bluelight History  |  Culture  |  About Us  |  Honor  |  Knowledge  |  Joining  |  Feedback  |  Service  |  Company profile  |  Sitemap  |  wholesale
© 2005-2024 blue-light Copyright, All Rights Reserved.
13th floor, Zhongli Enterprise Building No.92 Xudong Rd, Wuhan City, Hubei, China. Tel: 0086 27-86826688 86836688 0086-13720350106
E-mail: global@e-bluelight.com MSN 2412549315 cn209788248

Run 70 queries, spents 0.157358 seconds, 89 people online,Gzip enabled,take up memory 3.966 MB
客 服 中 心 Customer Service